A room gets booked because it holds the right number of people, and then somebody looks at the walls. A window wall that ruins every projection. Drape is where that goes, and it gets ordered as though there were only one kind of it.
There is not. Audio visual, or AV, is the screens and the sound, with lighting and staging beside it, and drape runs across all four. Knowing how to choose event draping means settling what the fabric has to do before anyone measures a wall, because four separate jobs want four different fabrics.
In short
- Drape does four jobs: hiding something, splitting a room, taming the sound, and being a backdrop you light. Each wants a different fabric.
- The two fabrics named below differ by most of their own weight again, and the weight decides the method.
- Fullness is the easiest line to drop from an order, and on one data pack it moves the fabric through three sound absorption classes.
- One exhibition handbook bars fixings to the building and rigging from the hall roof, so ask both questions before the drape is specified.
How to choose event draping starts with what it has to do
We want to know what an event is for before we specify anything, because equipment chosen before the job is understood is the wrong equipment. Drape is the clearest case of that on any kit list.
Hiding something is the first job: a service door, the back of a trade stand, a wall of radiators. Splitting a room is a different ask, because the fabric has to stand on its own and look finished on both sides. Taming the sound is third, and the fabric only does it if the brief says so. Being a backdrop is fourth, and a backdrop is a surface you are going to light.
That last job changes the lighting plan. Black drape keeps the light you were going to bounce off a pale wall, so the room goes darker and the fixtures move. Settle the drape and the lighting together, or the second one turns up designed around a wall that is no longer there. That is a reason to keep the two with one supplier: on the MLE fashion show and exhibition we supplied the draping for the catwalk area along with the staging, lighting, audio and camerawork.
The fabric has a weight, and the weight decides how it goes up
Weight is the first thing we settle, ahead of colour. J&C Joel’s Wool Serge 565 data pack gives 565 grams per square metre, woven 150 centimetres wide. ShowTex’s Molton CS gives 320 grams per square metre, woven 300 centimetres wide on rolls of 60 metres. Wool Serge 565 is listed for stage, masking, blackout and lining; Molton CS is listed as a masking fabric. One is most of its own weight again heavier than the other.
On a long wall that difference is the whole method: how many people are needed on the run, whether the head of the drape can go on a venue’s own bar or wants a truss. Roll width matters too, because 150 centimetres against 300 decides how many vertical joins land across the finished face.
Neither page publishes an opacity figure, though the ShowTex fabric sits in a category called dim and blackout. On both pages blackout is a description, not a measurement. If the drape has to kill daylight, that is a question to ask rather than a word to read.
Fullness is the line that changes what the room sounds like
Fullness is how much more fabric gets hung than the width being covered. At 50 per cent fullness a drape uses half as much again as the flat width, and at 100 per cent it uses twice.
J&C Joel publishes measured sound absorption for Wool Serge 565 hung flat and at both of those fullnesses, with the classes given against EN ISO 11654. Hung flat over a 100 millimetre cavity, the fabric comes out at absorption class D, noise reduction coefficient 0.60. At 50 per cent fullness over the same cavity it reaches class B and 0.80. At 100 per cent, class A and 0.85. Same fabric, same wall, three different results.
Fullness is also the easiest line to drop from a drape order, because the wall still looks covered without it. What changes is the room, because a long reverberation in a hard hall is what makes a speech difficult to follow. ShowTex says its Molton CS can shorten long reverberation times, and publishes no measured value. One supplier is handing you a class and a coefficient, the other a sentence.
Whether it hangs or stands is not your decision to make
Drape goes up one of two ways. It hangs, from a venue’s own bars or from a truss. Or it stands, on vertical uprights with a horizontal bar between them and weighted plates at the foot, which the trade calls pipe and drape. The first is tidier, the second eats floor.
Which one is available to you is set by the building and by whoever runs the show in it. One conference organiser’s exhibitor handbook, for its own 2026 event at ACC Liverpool, tells stand builders that fixings must not be made to the building structure, and that the suspension of stand fittings or lighting fittings from the hall roof will not be permitted. Where those rules apply, the drape stands on the floor, and that floor comes out of your plan, the same way a stage does.
One handbook is one handbook, and the rule varies. The habit carries over: get the answer in writing before the drape is specified, and ask it as two questions. May anything be fixed to the walls, and may anything hang from the roof. Both belong in the brief, alongside what your AV supplier needs from you.
Ask which fire certificate the drape carries
Both of these fabrics are sold as flame retardant, and both describe that property as inherent to the fabric. J&C Joel calls Wool Serge 565 inherently flame retardant and names BS 5867 Part 2 Type B for it. ShowTex calls Molton CS inherently and permanently flame retardant, and lists that same standard as a pass along with EN 13773 class 1 and a B-s1, d0 rating to EN 13501-1.
The awkward part is that the document asking you for a certificate may name different standards from the ones your drape holds. That same exhibitor handbook names BS 5438 and BS 5852 for fabrics, and says textile fabrics used for dressing purposes must be flameproofed. So the question is not whether a drape is flame retardant. It is which standards the certificate names, what inherent covers on the fabric you are being offered, and whether a copy can be sent this week rather than found on the morning of the build.
Frequently asked questions
Do we need the drape at full fullness, or will flat do?
It depends on whether the drape has an acoustic job. J&C Joel’s published figures put Wool Serge 565 at absorption class D hung flat and class A at 100 per cent fullness, so in a hard room where the speeches matter, the fullness is doing real work. If the drape is only hiding a door, flat is the honest answer.
Can we drape a room the venue will not let us fix anything to?
That is what pipe and drape is for. It stands on vertical uprights weighted at the foot, so nothing touches a wall and nothing hangs from the roof. What it wants instead is floor space along every run. Get the answer on fixings and rigging in writing from the venue and from whoever runs the show, because the method follows from it.
Sources
- Wool Serge 565 data pack · J&C Joel
- Molton CS, inherently flame-retardant molton · ShowTex
- UCISA26 Exhibitor Handbook · UCISA
If you are scoping drape for an event, send us the type of event, the date, the venue, and how many people will be in the room. With those we can tell you what that room will let you hang, what has to stand on the floor instead, and whether the drape has a job beyond covering a wall. We deliver nationwide.
Talk to us about event draping at eventproductiongroup.co.uk/contact or email hire@eventproductiongroup.co.uk.