Start from a headcount and the specification writes itself. Two hundred people, so a system for two hundred people. The number is real and it decides which room you book. It does not decide what that room needs, because the back row hears something different from the third row.
Audio visual, or AV, is the screens and the sound, with lighting and staging beside it. Knowing how to choose a sound system for an event starts with distances rather than headcounts, because distance is what makes the back of a room quieter than the front.
In short
- Headcount decides the room. The longest listening distance inside the room decides the system.
- QSC’s own placement guidance puts direct sound down by 6 decibels every time the distance from the loudspeaker doubles.
- d&b audiotechnik publishes a nominal dispersion for its E8 cabinet: 90 degrees across by 50 degrees up and down, rotatable.
- Ask what the difference will be between the loudest and the quietest seat. That is a specifiable number, and a kit list is not an answer to it.
How to choose a sound system for an event starts with distance
We want to know what an event is for before we specify anything, because equipment chosen before the job is understood is the wrong equipment. For sound, the useful version of that is two measurements and one question: how far the furthest seat sits from the stage, how wide the seating gets, and whether anything solid stands between the two.
Distance does predictable things. QSC’s own loudspeaker placement guidance describes direct sound dropping by half, which is 6 decibels, each time it doubles its distance from the source. A listener 24 metres back is two doublings down on one at 6 metres. That is why a room that sounded fine from the third row goes quiet at the wall, and it happens whatever the headcount is.
It also sets the kind of event this is written for. Our work is corporate: conferences, galas, awards nights and exhibitions, not consumer parties. A room where a speech has to land in the back row is a different specification from a room where a band plays to a dancefloor.
A loudspeaker covers a wedge, not a room
A cabinet does not spray sound everywhere. It has a pattern, and d&b audiotechnik publishes one for its E8 cabinet: a nominal dispersion of 90 degrees horizontal by 50 degrees vertical for its E8 cabinet, and says the horn is rotatable, giving 50 degrees across by 90 up and down.
Two things fall out of that for anyone scoping a room. The vertical figure is the smaller of the two, so the cabinet covers more width than height from where it is hung. And rotating that pattern is a decision somebody makes on your job.
Those figures belong to that cabinet. The question to put to a supplier is what the dispersion is on whatever is actually being offered, and how it has been aimed.
The number to ask for is a difference, not a volume
Loudness is the wrong thing to specify, because turning a system up does not even out what the seats hear. What matters is how much the sound varies between seats. QSC’s placement guidance sets the goal plainly: no more than a 6 decibel difference between the loudest and the quietest point in the audience.
That evenness is measurable, and there is a standard for measuring and classifying it. The Audiovisual and Integrated Experience Association, AVIXA, publishes A102.01:2022, Measurement and Classification of Audio Coverage Uniformity in Listener Areas. AVIXA says it defines parameters for characterising a sound system’s coverage of defined listener areas, and gives a procedure to measure and classify the uniformity of early arriving energy across a listener area.
The useful part is that the question has an answer: ask what the difference will be front to back, and expect a number rather than a kit list.
When the room is longer than the system, the answer is fills
At some point adding power at the front stops working, because the front rows get loud before the back rows get enough. QSC’s guidance for that case is direct: where the main public address, or PA, system does not adequately cover the whole audience area in a large or outdoor venue, the best solution is fill or delayed loudspeakers.
A fill is not simply another loudspeaker down the room. Sound takes time to travel, so the stage reaches a seat at the back later than a loudspeaker standing beside that seat does. We set the time on a fill before we set its level. A room that is hard and reverberant is a separate argument, and we make it in our post on sound at a gala dinner.
Speeches and a band are two specifications, settled at once
Your room may be doing more than one thing. If a conference has speeches in the morning, a panel after lunch and a reception at the end, each wants something different from the same loudspeakers. Speech wants intelligibility and a pattern aimed at seats. Music wants headroom and low frequency, pointed at a floor where people are standing rather than sitting.
One system can do both, and that is settled while it is being specified rather than during the band to DJ changeover. Tell a supplier what the room is doing hour by hour and the audio specification can carry all of it. Leave it out and the system gets specified for one of those jobs and then asked to do the other.
Frequently asked questions
How many loudspeakers does our room actually need?
It follows from the room, not the guest list. The longest listening distance, the width of the seating and the coverage angle quoted for the cabinet being offered are what set the count. Those figures decide the count, not the guest list, and a supplier who has walked the room can give you a number for it.
Should we add loudspeakers down the room, or a bigger system at the front?
Down the room, if the back rows are the problem. Pushing more power from the front makes the front louder before it makes the back adequate, because level falls with distance. Where the main PA does not adequately cover a large or outdoor venue, QSC’s guidance is fill or delayed loudspeakers, and those fills are timed to the stage as part of the specification.
Sources
- E8 loudspeaker, nominal dispersion angle · d&b audiotechnik
- Sound Advice, loudspeaker placement part 6: distributed loudspeakers · QSC Audio
- A102.01:2022, Measurement and Classification of Audio Coverage Uniformity in Listener Areas · Audiovisual and Integrated Experience Association
If you are scoping sound for an event, send us the type of event, the date, the venue and how many people will be in the room. The headcount tells us the room, the room tells us the distances, and the distances are what we need to say how many loudspeakers it takes and where they have to go. We deliver nationwide.
Talk to us about conference and corporate event sound at eventproductiongroup.co.uk/contact or email hire@eventproductiongroup.co.uk.